Softing OTX.studio is a tool for creating, implementing and debugging diagnostic and test sequences based on the ISO 13209 standard. With a simple GUI Editor or a QML script, it is easy to generate graphic user interfaces and link them to the sequences created. Furthermore various OTX templates are available, which make it much faster to implement sequences.
The OTX (Open Test sequence eXchange) standard compliant with ISO 13209 enables users to write simple test sequences for anything from function tests to complete tester applications. Softing OTX.studio supports the user in the specification phase and in subsequent implementation and validation. It makes it easy to create graphic sequence diagrams with a clear representation of the sequence logic. The integrated OTX Differ enables the convenient comparison and compilation of scripts of different development levels. The adaptation of existing sequences to new diagnostic data is effectively supported by special wizards.
Softing OTX.studio provides all the necessary input assistants. An automatic complete function allows users to create sequences without having indepth knowledge of the OTX language elements. Comprehensive project administration with integrated version management ensures a clear overview in large projects. The library concept that many users are familiar with from standard programming languages supports users in the implementation of application oriented and at the same time modular creation of their diagnostic sequences.
Typical areas of application are, for example, the creation of flash or test sequences. Particularly test planners for complete repair shop testers benefit from the integrated tools. The integrated GUI-Editor enables the simple designing of the entire test interface and the simple connection of interface elements to OTX scripts to graphically display variable values used. When creating complex GUI interfaces, an alternative to the builtin GUIEditor is to use QML scripts to describe the interfaces and graphic components. There is also no limitation to the number of OTX function libraries that can be used. Developers of programs for guided fault search on the vehicle, use the foreign language editor, the document viewer and browser for repair instructions and technical drawings. The comprehensive debugging possibilities are indispensable for all users.
For the most frequent diagnostic sequences, such as, for example, ECU identification, reading measurement data and the fault memory, I/O test, ECU exchange and software update, Softing OTX.studio provides the user with OTX templates which can be configured from the ODX authoring using a simple „Drag & Drop“ process. Using the OTX template ensures not only the generation of a full-fledged OTX sequence but also a graphic user interface that suits the sequence. If required, both can be adapted to specific requirements and can also be modified.
The frequent case of having to test a diagnostic service can either be elaborately programmed or configured simply with the Test Case-Editor (TCE). For this purpose, diagnostic services are dragged and dropped into the test case specification and then configured in terms of parameterization, the target result and the response to deviations. This procedure can also be used for the fast and simple creation of elaborate test tasks. The OTX sequence is then generated automatically at the end at the push of a button. This can be reworked manually at any time.
Supported Hardware Interfaces | |
Softing EDIC Interfaces | EDICusb, EDICblue, EDICpci, EDICwlan, EDICcard2 |
Softing VIN|ING Interfaces | VIN|ING 600 (WLAN Ethernet bridge for DoIP) |
Softing CAN Interfaces | CANpro USB, CANusb, CAN-PRO2-PCIE, CAN-AC2, CANcard2 |
KVASER CAN Interfaces | Leaf Professional HS, Leaf Light HS, Leaf Light HS v2, Memorator Pro HS/HS, USBcan II HS/LS,PCIcanx HS/HS, PCIEcan HS/HS |
Third Party Interfaces | On request |
Order Numbers | |
PDUAPI-EC | D-PDU API software license (ISO 22900-2), for use without DTS or OTX products for CAN and PassThru interfaces (SAE J2534) as well as for DoIP (ISO 13400) without VCI |
PDUAPI-LIC | D-PDU API software license (ISO 22900-2), for use together with DTS or OTX products for CAN and PassThru interfaces (SAE J2534) as well as for DoIP (ISO 13400) without VCI |
Supplementary Products and Services | |
DTS8L+MONACO | All-in-one engineering tester DTS 8 Monaco for diagnostic and control functions of vehicle ECUs which comprehensively covers all tasks in the areas of engineering, testing and preparation of manufacturing tests |
Download | |
Datasheet | D-PDU API - Standardized Vehicle Access via D-PDU API |
Software | For your free D-PDU API Version 11.26.001 please contact: info.automotive[at]softing[dot]com Download MVCI D-PDU API Software Version 11.26.001:This software package is based on ISO 22900-2 International Standard First Edition 2009-02-01 (Part 2, specification release version 2.2.0). It can be used with all EDICusb, EDUCblue, EDICcard2, EDICpci and EDICwlan hardware interfaces from Softing delivered after 1st of July 2010. Operating this software with EDIC interfaces from before that date requires purchase of a special license. The software license for D-PDU API can be obtained for free when operating with one of the CAN interfaces from Softing or Kvaser together with DTS or OTX products.
|